JIS G3114 SMA490CP Weathering Steel Plate for Bridges

Nov 21, 2025 Leave a message

What SMA490CP Is

SMA490CP is one of the atmospheric corrosion resisting steel plate grades of JIS G3114, the Japanese standard for hot-rolled weathering steel. The 490 in the designation marks the strength class, giving a tensile range of 490-610 MPa, and the grade is produced with a copper and chromium addition that allows the exposed surface to form a dense, adherent oxide layer. That layer, once developed, slows the rate of further atmospheric corrosion dramatically compared with an unprotected carbon steel surface, which is why the grade is used without painting on bridges, transmission towers, building frames and other structures that are difficult or expensive to repaint.

Chemical Composition

Element SMA490CP limit
Carbon 0.18 % maximum
Silicon 0.55 % maximum
Manganese 1.40 % maximum
Phosphorus 0.035 % maximum
Sulphur 0.035 % maximum
Copper 0.20-0.35 %
Chromium 0.30-0.55 %

Copper is the element that gives weathering steel its name: in the presence of alternate wetting and drying it promotes the formation of a protective oxide layer rather than loose rust. Chromium reinforces that layer and improves its adhesion, while the carbon ceiling at 0.18 % and the phosphorus and sulphur ceilings at 0.035 % keep the steel weldable, which is the practical difference between a weldable weathering plate and the older, higher-phosphorus corrosion resisting steels that were not suitable for welding. Carbon equivalent is calculated from the heat analysis and reported so that the welding procedure can be set accordingly.

Mechanical Properties

Property SMA490CP requirement
Minimum yield strength 355 MPa
Tensile strength range 490-610 MPa
Minimum elongation 21 % for the common thickness range
Impact test temperature 0 °C, with the minimum absorbed energy fixed by JIS G3114
Delivery condition Hot rolled

The 355 MPa minimum yield strength and the 490-610 MPa tensile range place the grade in the middle of the structural strength spectrum, comparable to the S355 class in the European system. Elongation is tabulated by thickness in the standard, and the impact requirement is met by Charpy V-notch testing at 0 °C. Because the plate is supplied hot rolled, the properties depend on the rolling practice and on the copper and chromium content rather than on a heat treatment step.

Welding and Fabrication

SMA490CP is designed for welded construction, and the low carbon, low phosphorus chemistry is what makes that possible. Plate is cut by flame, plasma or laser, edges are prepared for welding, and joints are welded with consumables matched to the 490-610 MPa tensile level. Carbon equivalent control keeps preheat requirements modest in normal thicknesses, while heavy sections, high restraint and low ambient temperature call for preheat and hydrogen-controlled consumables under a qualified procedure. The corrosion resistance of a weathering steel depends on the surface staying alternately wet and dry, so fabrication practice matters: standing water must not be trapped in joints and details, drainage holes are provided at low points, and weld spatter and embedded foreign metal are removed because they prevent the protective oxide layer from forming evenly. Painting is often omitted entirely, but the steel is not suitable for permanent immersion in water or for locations where chloride from sea spray or de-icing salt accumulates without washing, and in those positions a protective coating system is still required.

Applications and Supply

Bridges, buildings, transmission and communication towers, shipping containers, vehicle structures and other exposed steelwork are the main applications. Plate is supplied hot rolled in thicknesses from about 3 mm to 100 mm, in cut-to-size widths and lengths, with cut edges, drilled holes and beveled weld preparations provided where the fabrication drawing is final. Where the plate will be exposed, edges from flame cutting are dressed and blast cleaning is carried out to a specified surface preparation grade before any coating is applied, because the oxide layer only forms on a clean, uniform surface. Ultrasonic examination to an agreed acceptance class, thickness-direction testing to Z15, Z25 or Z35 and independent third-party inspection are all available. Certification is issued as a mill test certificate showing heat number, chemical analysis including copper and chromium, tensile and yield results, elongation and impact energy at 0 °C, and plates are marked with grade and heat number and shipped with edge protection by container or break bulk.

Frequently Asked Questions

Q: What is SMA490CP used for?

A: Bridges, buildings, towers, containers and vehicle structures, particularly where the steel is left unpainted and exposed to the atmosphere for a long service life.

Q: How does weathering steel resist corrosion?

A: Copper and chromium additions allow the surface to form a dense, adherent oxide layer during alternating wet and dry cycles, and that layer slows the rate of further atmospheric corrosion.

Q: What is the tensile strength of SMA490CP?

A: The tensile range specified in JIS G3114 is 490-610 MPa, with a minimum yield strength of 355 MPa and an elongation requirement tabulated by thickness.

Q: Does SMA490CP need painting?

A: In the right exposure conditions it can be left unpainted, which is the point of the grade. In chloride-rich or permanently wet locations a coating system is still required because the protective oxide layer will not form properly.

Q: Why is phosphorus limited in this grade?

A: Phosphorus is capped at 0.035 % so that the plate remains weldable. High-phosphorus corrosion resisting steels were not suitable for welded bridge and building construction.

Q: What testing accompanies the plate?

A: A mill test certificate with heat number, chemical analysis including copper and chromium, tensile and yield results, elongation and Charpy energy at 0 °C, with ultrasonic examination and thickness-direction testing available as optional requirements.