What S355J0WP and S355J2WP steel plates are
Both grades belong to the European standard for atmospheric corrosion resistant structural steels, EN 10025-5. They are weathering steels: a controlled amount of alloying elements such as phosphorus, copper, chromium, nickel and molybdenum is added to the steel so that, under the influence of alternating wet and dry climatic conditions, an adherent protective oxide layer forms on the base metal and slows further atmospheric attack.
The two designations share almost the entire specification. S means structural steel, 355 is the minimum yield strength in MPa, and WP identifies the high-phosphorus weathering variant. The only letter that separates them is the impact quality class: J0 requires impact testing at 0 degrees Celsius and J2 requires impact testing at minus 20 degrees Celsius. S355J0WP and S355J2WP plates and sheets are used for low-alloy steel structures such as vehicles, bridges, towers, masts and containers, where a long service life without painting is the main economic argument.
Chemical composition compared
The values below are the melting analysis limits of EN 10025-5 for the two grades.
| Element, % | S355J0WP | S355J2WP |
| C, max | 0.15 | 0.15 |
| Si, max | 0.80 | 0.80 |
| Mn, max | 1.10 | 1.10 |
| P | 0.05-0.16 | 0.05-0.16 |
| S, max | 0.040 | 0.035 |
| N, max | 0.010 | - |
| Cr | 0.25-1.35 | 0.25-1.35 |
| Cu | 0.20-0.60 | 0.20-0.60 |
The chemistry is essentially identical, and that is the reason the two grades are usually treated as one purchasing family. Phosphorus is deliberately held in the range 0.05-0.16 %, the highest level tolerated in a structural steel, because phosphorus is one of the elements that makes the rust layer protective. Copper between 0.20 % and 0.60 % and chromium between 0.25 % and 1.35 % complete the weathering package. The only compositional difference shown is sulphur: the J0 grade is allowed up to 0.040 % and the J2 grade up to 0.035 %, and the J2 grade additionally carries a nitrogen limit in the same specification family. Cleaner sulphur and nitrogen support the lower impact test temperature.
Mechanical properties and thickness ranges
| Property | S355J0WP | S355J2WP |
| Yield strength ReH, min, up to 16 mm | 355 MPa | 355 MPa |
| Yield strength ReH, min, 16-40 mm | 345 MPa | 345 MPa |
| Tensile strength Rm, thin sheet | 510-680 MPa | 510-680 MPa |
| Tensile strength Rm, plate to 100 mm | 470-630 MPa | 470-630 MPa |
Strength is identical, because the J0 and J2 symbols describe toughness rather than load capacity. Minimum yield strength is 355 MPa for thicknesses up to 16 mm and 345 MPa for plates from 16 mm to 40 mm; heavier sections are ordered by agreement between buyer and supplier. Tensile strength follows the same pattern, at 510-680 MPa for thin material and 470-630 MPa for plate up to 100 mm. Designers can therefore use the same section calculation for either grade and select between them purely on the impact requirement.
Impact toughness: the J0 and J2 difference
Charpy V-notch impact testing on longitudinal specimens is the one measurable difference between the two plates.
S355J0WP is tested at 0 degrees Celsius with a minimum absorbed energy of 27 J.
S355J2WP is tested at minus 20 degrees Celsius with a minimum absorbed energy of 27 J.
Both values are minimum averages for the specified test temperature, and they are verified by an inspection certificate issued with the plates. The practical consequence is climatic and geometric. A structure that will only ever see mild, non-freezing service can be built from the J0 grade at slightly lower cost. A structure exposed to winter conditions, a cold store, a vehicle frame or a heavily restrained welded joint, where the risk of brittle fracture rises as the temperature falls, should be built from the J2 grade. Because the weathering chemistry is the same, upgrading from J0 to J2 does not change the corrosion performance of the steel.
Corrosion behaviour and where each grade is used
Weathering steel works by design in a specific environment. In exposed conditions with regular wet and dry cycles, the surface of S355J0WP or S355J2WP develops a stable, tightly adherent oxide layer that seals the surface and reduces the corrosion rate to a fraction of that of ordinary carbon steel. The mechanism needs oxygen and drying periods to work, so the grades are not suitable for permanent immersion in water, for burial in soil, for crevices that stay wet, or for atmospheres heavily loaded with chlorides or aggressive chemicals.
Bridges, overpasses and highway structures, often left unpainted where drainage and detailing allow the rust layer to stabilise.
Transmission towers, poles, masts, sign gantries and lighting columns.
Railway rolling stock, wagon bodies, container frames and chassis.
Vehicle and transport equipment exposed to weather but not to sustained immersion.
Architectural and industrial building structures where the brown patina is part of the design intent.
In all of these applications the J2 variant is the safer default where low winter temperatures, impact loading or heavy restraint are present, while the J0 variant is fully adequate in temperate service.
Welding, forming and ordering notes
Welding: use low-hydrogen consumables and a qualified welding procedure. Keep heat input and interpass temperature under control, and avoid unrestrained fast cooling of thick sections, so that the toughness verified by the J0 or J2 test is retained in the joint.
Detailing: weathering steel demands good detailing. Water must be able to drain away and crevices must be sealed, or the protective layer will not form and local corrosion will concentrate in exactly the place it is hardest to repair.
Forming: both grades are ductile structural steels and can be cold formed, bent and punched using normal structural steel practice; the higher phosphorus content slightly increases the tendency to work harden, so tight radii should be avoided.
Ordering: state the standard, the grade including the impact class, the thickness, the delivery condition and the required inspection certificate. Because the strength and chemistry of the two grades are the same, the impact class is the decisive purchasing instruction.
Frequently asked questions
Q: What is the difference between S355J0WP and S355J2WP steel?
The difference is the impact test temperature. S355J0WP is guaranteed at 0 degrees Celsius and S355J2WP is guaranteed at minus 20 degrees Celsius, both with a minimum longitudinal Charpy V-notch energy of 27 J. Chemical composition and mechanical strength are the same.
Q: Do both grades have the same yield strength?
Yes. Both have a minimum yield strength of 355 MPa up to 16 mm thickness and 345 MPa from 16 mm to 40 mm, with tensile strength in the range 510-680 MPa for thin material and 470-630 MPa for plate to 100 mm.
Q: Why is phosphorus allowed up to 0.16 % in these steels?
Phosphorus in the range 0.05-0.16 % is a deliberate alloying addition. Together with copper and chromium it promotes the formation of the dense protective oxide layer that gives weathering steel its atmospheric corrosion resistance.
Q: Can S355J0WP be substituted for S355J2WP?
Not freely. Substituting the J0 grade means losing the guaranteed toughness at minus 20 degrees Celsius, so any structure subject to low-temperature service or impact loading needs engineering approval before the change is accepted.
Q: Is weathering steel suitable for marine environments?
Normally not. Chloride-rich marine atmospheres prevent a stable protective layer from forming and can cause severe localised attack, so these grades are specified for atmospheric exposure away from salt spray and permanent moisture.
Q: What thickness range is available?
EN 10025-5 covers thin sheet and plate up to 150 mm, with the specified minimum yield and tensile strengths tabulated by thickness. Heavy plates beyond the tabulated range are supplied by agreement between buyer and supplier.