13MnNiMoR Steel Plate for Boiler and Pressure Vessels

Jan 19, 2024 Leave a message

What 13MnNiMoR Is

13MnNiMoR is a boiler and pressure vessel steel plate from the manganese-nickel-molybdenum family. The designation records the nominal carbon content, the alloying elements manganese, nickel and molybdenum, and the final letter R that marks steel for pressure vessels. The combination of manganese for strength, nickel for toughness in thick sections and molybdenum for elevated temperature stability is aimed squarely at heavy wall equipment where a plain carbon steel would need excessive thickness.

The grade is used across a broad band of medium and low temperature pressure equipment. It shows up in petroleum, chemical, fertiliser and power plants, and in practice it is one of the workhorse grades for vessels that must combine a moderate design temperature with substantial wall thickness.

Standard, Delivery Condition and Ordering

13MnNiMoR is produced to GB/T 713.2-2023, the part of the steel plate and strip standard for pressure equipment covering non-alloy and alloy steels with specified temperature properties. The specification fixes grade representation, ordering content, dimensions, shape and mass, technical requirements, test methods, inspection rules, packaging, marking and quality certificate content.

The delivery condition is normalised and tempered. The tempering temperature is not lower than 620 degrees Celsius, which is high enough to soften the heat affected zones and to give the plate the toughness needed for vessel service. For plate thicker than 50 mm, with purchaser agreement, the material may be supplied normalised with accelerated cooling followed by tempering, a route that suits heavy plate where a plain normalising treatment would not develop the required properties through the full thickness.

Mechanical Properties

Property Thickness range Requirement
Yield strength 6 to 100 mm 390 MPa minimum
Yield strength over 100 to 150 mm 380 MPa minimum
Tensile strength all sizes 570 to 720 MPa
Elongation after fracture all sizes 18 % minimum
Charpy V-notch impact energy all sizes 47 J minimum at 0 degrees Celsius
Bend test all sizes 180 degrees with mandrel diameter D = 3a

The yield requirement steps down slightly beyond 100 mm thickness, a normal pattern that reflects the slower cooling and lower reduction ratio of heavy plate. Design calculations should use the value that corresponds to the thickness actually ordered.

Where the Plate Is Used

Because the grade performs as a medium and low temperature pressure vessel steel, its applications are concentrated in heavy process equipment. The list includes reactors, heat exchangers, separators, spherical tanks, oil and gas tanks, liquefied gas tanks, nuclear reactor pressure shells, boiler steam drums, liquefied petroleum gas cylinders, high pressure penstocks for hydroelectric stations and turbine spiral cases. In each case the common requirement is a thick wall that has to remain tough in service.

Fabrication, Inspection and Quality Control

Forming: cold forming within agreed deformation limits; hot formed parts require a heat treatment that restores the normalised and tempered properties.

Welding: low hydrogen consumables matched to the strength class, with preheat and interpass temperature controlled for thickness, and post-weld heat treatment for heavy or restrained joints.

Non-destructive testing: ultrasonic testing sheet by sheet to JB/T 4730.3 or GB/T 2970 where specified.

Mechanical testing: tensile, impact and bend tests in the delivery condition, with simulated post-weld heat treatment available.

Documentation: heat number traceability and a quality certificate issued in line with GB/T 247.

Frequently Asked Questions

Q: What is the delivery condition of 13MnNiMoR plate?

A: Normalised and tempered, with a tempering temperature not below 620 degrees Celsius.

Q: What is the yield strength of the grade?

A: At least 390 MPa for plate from 6 mm to 100 mm and at least 380 MPa for plate over 100 mm up to 150 mm.

Q: Which standard applies?

A: GB/T 713.2-2023 for non-alloy and alloy steel plates for pressure equipment with specified temperature properties.

Q: Can very thick plate be supplied by a different heat treatment route?

A: Yes, plate over 50 mm may be supplied normalised with accelerated cooling and then tempered, subject to purchaser agreement.

Q: What impact test requirement is typical?

A: A minimum Charpy V-notch absorbed energy of 47 J at 0 degrees Celsius.