1. Yield Strength Requirements
LR defines minimum yield strength values to ensure load-bearing capacity.
Standard Grades:
LR Grade A: ≥235 MPa.
LR Grade EH36: ≥355 MPa.
Testing Method:
Tensile tests per ISO 6892-1 at room temperature (20°C).
Samples taken transversely from plates >20mm thick.
Thickness Impact:
Yield strength may decrease by 10–15 MPa for plates >50mm due to cooling rate variations.
LR Rule Reference: Pt.3, Ch.2 of LR Rules for Materials.
2. Tensile Strength (Rm) and Ductility
LR mandates tensile strength ranges and minimum elongation for structural reliability.
Typical Ranges:
Grade A: 400–520 MPa.
EH36: 490–620 MPa.
Elongation (A₅₀):
Grade A: ≥22% .
EH36: ≥21%.
Fracture Control:
Reduction of area (Z) ≥45% for critical applications (e.g., hull girders).
Note: TMCP-processed steels often show higher elongation than normalized grades.
3. Charpy Impact Toughness
LR specifies impact energy values at designated temperatures.
Test Conditions:
Charpy V-notch (CVN) per ISO 148-1.
Sample Orientation: Longitudinal (L) or transverse (T).
Grade-Specific Requirements:
Grade D: ≥27J at -20°C (L-T direction).
EH36: ≥34J at -40°C (both L-T and T-L for ABS equivalence).
Arctic Grades:
EH40 Arctic: ≥60J at -60°C (additional thickness constraints).
Testing Frequency: 1 test per 50 tons for LR-certified batches.
4. Bend Test Performance
Bend tests validate formability and surface integrity.
Standard Requirements:
180° bend test with mandrel diameter = 2× plate thickness for Grade A.
No cracks allowed after bending.
High-Strength Steels:
EH36/FH40: May require 3× thickness mandrel due to reduced ductility.
Alternative Tests:
Guided bend tests for weld procedure qualifications.
LR Compliance: Bend tests are mandatory for as-rolled plates but waived for TMCP grades with proven toughness.
5. Through-Thickness (Z-Direction) Properties
LR enforces Z-testing for thick plates to prevent lamellar tearing.
When Required:
Plates >40mm thick in highly restrained joints (e.g., T-joints).
Acceptance Criteria:
Z25: Minimum 25% reduction of area.
Z35: Required for ice-class vessels (35% reduction).
Testing Standard:
ISO 27306 for Z-direction tensile tests.
Case Study: LR rejected a 60mm EH36 batch due to Z-test results <20%.